Fireray 5000 logo

Fireray® 5000

AUTO-ALIGNING BEAM SMOKE DETECTION FOR LARGE & OPEN SPACES

The Fireray® 5000 System is an auto-aligning, self-correcting infrared reflective Beam Smoke Detector. Up to 2 Detector heads can report to a single ground level controller. In addition, each system controller houses two pairs of fire and trouble relays, one per Detector. Once the Detector head is installed, using the easy fit mounting system, an integral LASER can be activated. This allows the reflective Prism to be located quickly with confidence. 

The Auto-Align function ensures proper alignment and maximum signal during the Beam installation. Building Movement TrackingTM automatically steers and maintains the Beam in the optimum position for reliable performance. The signal generated in the Transmitter element and reflected by the Prism back to the Receiver element is analyzed for the presence of smoke. The internal microprocessor determines an alarm condition when a predetermined level obscuration is reached. 

The system is designed to be mounted so the Beam will project between 19” (0.5m) and 24” (0.6m) below the ceiling. Lateral detection may be up to 30ft. (9.144m) on either side of the Beam, providing a maximum total coverage area of up to 19,800 square feet (60ft. x 330ft. or 18.29m x 100m). For installations complying with UL268/NFPA72, the maximum distance of Detector and Reflector from the ceiling must be 10% of the distance between floor and ceiling

PRODUCT FEATURES
  • Separate Transmitter and Receiver Heads – Up to two detector heads reporting to one low level controller.
  • Wide Detection Range – 26.2 to 328 feet (50 to 100 meters)

  • Integral Laser Alignment – Built-in laser assisted Prism mounting.

  • Automatic Alignment – Completed in 2–4 minutes per head.

  • Building Movement Tracking – Auto correction due to building shift
  • Customizable Fire and Fault Relays – Independent signalling for alarms and faults, with programmable alarm thresholds and alarm delays

  • Low Current Draw – Requires 5–8.5 mA.

  • Programmable Sensitivity & Thresholds – Customize alarm settings.

  • Built-In UL/ULC/FM Fire Test – Internal electronic obscuration verification.

  • Easy Installation – Knockouts for fast wiring.

Mechanical

  • Housing: Flame Retardant PC UL94 V0 IP
  • Rating: IP54
  • Finish: Light Grey/Black
  • Weight: Head & Controller 3.24 lbs (1.47 kg)
  • Dimensions:
    • Head: 5.28” H x 5.16” L x 5.28” W (134mm H x 131mm L x 134mm W)
    • Controller: 3.43” H x 9.06” L x 7.95” W (87mm H x 230mm L x 202mm W)
    • Prism: 0.37” H x 4.13” L x 3.94” W (9.5mm H x 105mm L x 100mm W)


Electrical

  • Primary Input Power: 14 to 36 VDC
  • Standby Current: Low Current Mode: 5mA to 8.5mA @ 24VDC depending on number of detector heads used High Current Mode: 37mA @ 24VDC
  • Alarm Current: – 5mA to 8.5mA @ 24VDC depending on number of detector heads used
  • Relay Contacts: 1A @ 30VDC Resistive
  • Reset Time: 5 Seconds maximum
  • Start Up Time: 45 Seconds
  • Optical Wavelength: 850nm
  • Alarm Threshold: 10% – 60% (35% Default)
  • Temperature Rating: -4°F to 131°F (-20°C to 55°C) For UL Listed Installations: 32°F to 100°F (0°C to 38°C)
  • Relative Humidity: 0% to 93% RH non-condensing
  • Range: 26.2 ft to 328 ft (8 m to 100 m)
  • Cabling Between each Detector & Controller: 18-14 AWG 1-Pair
  • Airports & Aircraft Hangars
  • Warehouse & Storage Facilities
  • Manufacturing & Food Processing
  • Diesel Generators & Fuel Storage
  • Battery Rooms & Charging Facilities
  • Oil & Gas Facilities
  • Refineries & Cogeneration Plants
  • Chemical & Hydrogen Plants
  • Tank Farms
  • Compressor Stations
  • Paint Booths
  • Paint & Solvent Storage Facilities
  • Recycling Centers
  • LPG / LNG Facilities
  • Power Plants
  • Marine Fuel Loading & Unloading
  • 5000-103: Reflective Auto Align Beam Smoke Detector 16ft. to 330ft. (5m to 100m). System includes 1 Detector Head, 1 Controller and 1 Prism.

  • 5000-031: Additional Detector Head and 1 Prism – Use up to one additional Head per 5000-103

  • 5000-005: Universal Alignment Bracket – Used with F-5000 Detector Head, 5000-007 and 5000-008

  • 5000-201: Universal 130 Alignment Bracket – Used with F-5000 Detector Head, 5000-007 and 5000-008

  • 5000-003: System Controller

  • 1030-000: Reflector Wall Bracket (white in color)

  • 1031-000: Reflector Wall Bracket (black in color)

  • 5000-007: 4 Prism Alignment Adaptor Plate

  • 5000-008: 1 Prism Alignment Adaptor Plate

  • 5000-009: Controller Back Box

  • 5000-010: Semi-Flush Trim Plate for 5000-009

  • 5000-011: Detector Surface Mount Uni-Box

  • 5000-012: Detector 2 gang Mounting Plate

  • 5000-014: Ceiling Pendant Mount Bracket

  • 1000-018: Wire Protective Cage for Detector

  • 1000-019: Wire Protective Cage for Controller

  • 23901.01: Replacement Prism

  • UL – S3417

  • ULC – S3417

  • MEA – 22-08-E

  • CSFM – 7260-1508-104

  • FM Approved

  • Maryland – 2243