D1xC1X05F Alarm Horn & 5J Xenon Strobe

THE D1XC1X05F IS A GLOBALLY CERTIFIED ALARM HORN SOUNDER FEATURING A RE-ENTRANT FLARE HORN AND COMBINED WITH A 5 JOULE XENON STROBE BEACON. ROBUST TYPE 4/4X, IP66 MARINE GRADE, CORROSION PROOF ALUMINIUM ENCLOSURE APPROVED FOR CLASS I & II DIV 1, ZONE 1 & 20, IECEX AND ATEX ZONE 1, 2, 21 & 22 EXPLOSION PROOF SIGNALLING APPLICATIONS.
DESCRIPTION
Featuring 64 alarm tone sounds, each of the available 4 stage/channels can be remotely triggered. Class D amplification provides a high sound output at optimum operating current. The threaded flameproof joint, multiple cable entries and duplicated, pluggable termination simplifies both installation and routine maintenance. The 24Vdc Class I version is approved for public (alarm horn) and private mode fire alarm use (strobe beacon).

Maximum sound pressure level output of 115dB(A)
Automatic synchronisation on multi-beacon & sounder systems
UL464 / CAN/ULC-S525 & UL1638 / CAN/ULC-S526

Alarm Horn:
Maximum output: 115dB(A) @ 1 metre [106dB(A) @ 10ft/3m] Class II version: 98dB(A) @ 1 metre [88dB(A) @ 10ft/3m]
Nominal output: 110dB(A) @ 1m +/- 3dB – Tone 4 [101dB(A) @ 10ft/3m] Class II version: 94dB(A) @ 1 metre [84dB(A) @ 10ft/3m]
No. of tones: 64 (UKOOA / PFEER compliant)
No. of stages: 4
Volume control: Full range
Effective range: 125m/410ft @ 1KHz
Voltages DC: 24Vdc (20-28Vdc)
Voltages AC: 110-120Vac, 220-240Vac
Stage switching: DC units: negative or positive AC units: common supply line
Strobe Beacon:
Energy: 5 Joules (5Ws)
Flash rates: Option 1: 1Hz (60 fpm) Option 2: 1.5Hz (90 fpm) Option 3: Double Strike
Eff. Intensity: 143 cd* – measured ref. to I.E.S.
Peak Candela: 46,976 cd* – measured ref. to I.E.S.
Eff. Intensity: 250 cd – calculated from energy (J)
Peak Candela: 500,000 cd – calculated from energy (J)
Lens colours: Amber, Blue, Clear, Green, Magenta, Red & Yellow
Tube life : Emissions reduced to 70% > 5 million flashes
General:
Ingress protection: EN60529: IP66 UL50E / NEMA250: 4 / 4X / 3R / 13
Enclosure material: Marine grade aluminium LM6 – copper free Chromated & powder coated – corrosion proof
Enclosure colour: Red or Grey, custom colours available on request
Cable entries: 1×1/2″NPT & 2xM20 – thread adaptors available
Terminals: 0.5 – 2.5mm² (20-14 AWG) Pluggable, duplicated terminals
Grounding stud: M5
Line monitoring: Blocking diode included. EOL Min. 500 Ohm 2W, or 3k3 Ohm 0.5W resistor or diode (DC versions) can be fitted
Enclosure volume: <2 litres
Installation temp: -55 to +85°C [-67° to +185°F]
Storage temp: -55 to +85°C [-67° to +185°F]
Relative humidity: 99%
Vibration test: 35Hz for a duration 4Hr (UL464)
Jarring test: 3ft/lb Energy (UL464)
Impact test: 3x 5lb (UL464)
Relative humidity: 95% – Additional tropicalisation is recommended for applications where both high relative humidity and high ambient temperatures exist
Weight: 5.2kg/11.4lbs
 

Nominal Voltage: Voltage range: Xenon Strobe Nominal current: Alarm Horn Nominal current: Combined Nominal current: Combined Max. current:
24Vdc 20-28Vdc 323mA 185mA 508mA 555mA
115Vac 110-120Vac 50/60Hz 129mA 73mA 200mA 264mA
230Vac 220-240Vac 50/60Hz 79mA 48mA 127mA 149mA

Part Code: Identifier: Description:
Product type: D1xC1X05 Combined Alarm Horn & Xenon Strobe
Horn type: F Flare re-entrant horn
Voltage: DC024 AC115 AC230 20-28V dc 110-120Vac 220-240Vac
Cable entries:[e] A B C D E Note: 1×1/2″NPT, 2xM20 1×1/2″NPT, 2×1/2″NPT-adaptors 1×1/2″NPT, 2×3/4″NPT-adaptors 1×1/2″NPT, 1 x M20, 1×1/2″NPT-adaptor 1×1/2″NPT, 1 x M20, 1×3/4″NPT-adaptor All entries, excluding thread adaptors, supplied with stopping plugs installed.
Stopping plug/ adaptor material: [m] B N S Brass Nickel Plated Stainless Steel
Bracket/Guard material: [s] 1 3 A4 316 Stainless Steel A4 316 St/St with Equip. Tag
Product version: [v] A D UL, cUL, ULC, IECEx, ATEX, PESO, CSFM Class II – UL, cUL
Product option: [o] 1 Z T X Y Standard product Custom alarm tone software – contact E2S Tropicalisation Custom configuration – contact E2S Stage control Config. 4
Enclosure colour: [x] G R Grey Red
Lens colour: [y] A B C G M R Y Amber Blue Clear Green Magenta Red Yellow
Accessories:
SP65-0001-A4 SP65-0003-A4 Pole Mount Bracket Kit 2″ St/St A4 (316) Sunshade – St/St A4 (316)

UL/cUL/ULC File ref: E230764
IECEx Certificate: IECEx ULD 19.0008X
ATEX Certificate: DEMKO 19 ATEX 2141X
CSFM listing: 7136-2279:0506
UKCA certificate: UL21UKEX2132X

NEC Class / Zone Class I Zone 1 IIC T4 Gb Ta -55°C to +85°C Class I Zone 1 IIC T4A Gb Ta -55°C to +80°C Class I Zone 1 IIC T5 Gb Ta -55°C to +60°C Class I Zone 1 IIC T6 Gb Ta -55°C to +45°C
CEC Class / Zone Class I Zone 1 IIC T5 Gb Ta -55°C to +55°C Class I Zone 1 IIC T6 Gb Ta -55°C to +45°C
NEC / CEC Class / Div Class I Div 1 ABCD T5 Ta -55°C to +55°C Class I Div 1 ABCD T6 Ta -55°C to +45°C
IECEx / ATEX II 2G Ex db IIC T4 Gb Ta -55°C to +75°C II 2G Ex db IIC T5 Gb Ta -55°C to +55°C II 2G Ex db IIC T6 Gb Ta -55°C to +40°C (DC only) II 2D Ex tb IIIC T115°C Db Ta ‐55°C to +75°C
NEC Class / Zone – Product version: D Class II Zone 20 IIIB T4A Gb Ta -55°C to +70°C Class II Zone 20 IIIB T5 Gb Ta -55°C to +60°C Class II Zone 20 IIIB T6 Gb Ta -55°C to +45°C
NEC Class / Div – Product version: D Class II Div 1 Group FG T4A Ta -55°C to +70°C Class II Div 1 Group FG T5 Ta -55°C to +60°C Class II Div 1 Group FG T6 Ta -55°C to +45°C Class III Div 1 Ta -55°C to +70°C See product manual for full voltage specific coding.