Four flash rates: 1Hz, 1.3Hz, 1.5Hz & double flash
Automatic synchronisation on multi-beacon system
User replaceable Xenon tube secured against shock & vibration
Stainless Steel guard included as standard
Field replaceable UV stable lens colour filter
Stopping plugs included
4 x side cable entries, 1 x pendant conduit entry
Duplicate cable terminations (in & out for daisy-chain installations)
UL 1638 Visible signaling devices for Fire Alarm
CAN/ULC S526 Visible signaling device for Fire Alarm
Source: Xenon Strobe
Energy: 15 Joules
Modes: 1Hz flash (60 fpm)
1.3Hz flash (80 fpm)
1.5Hz flash (90 fpm)
Double flash (120 fpm)
Eff. Intensity cd: 98.61cd UL1638 Private mode fire
Eff. Intensity cd: 731.71cd measured ref to I.E.S
Peak Intensity cd: 1,500,000 cd
Lens colours: Amber, Blue, Clear, Green, Magenta, Red & Yellow
Voltage DC: 24V dc (20-28Vdc), 48Vdc (42-54Vdc)
Voltage AC: 115Vac (110-120Vac), 230Vac (220-240Vac)
In-rush: 753mA within 6ms @ 24Vdc
Ingress protection: IP rating per EN60529:IP66
Type rating per UL50E/NEMA250:4/4X/3R/13
Enclosure matl: Marine grade LM6 aluminum alloy
Enclosure finish: Chromate & powder coated finish – anti-corrosion
Enclosure color: Red (RAL3000) or Grey (RAL7038)
Lens material: High impact Borosilicate glass
Cable entries: Side: 2 × 3/4″NPT & 2 x M20x1.5
Pendant: 1 × 3/4″NPT
Stopping plugs: Brass, Nickel Plated or Stainless Steel
Terminals: 0.5 – 2.5mm² (20-14 AWG)
Line monitoring: Blocking diode included
EOL can be factory or user installed
Installation temp: -55 to +80°C [-67° to +176°F]
Storage temp: -55 to +80°C [-67° to +176°F]
Relative humidity: 95% – Additional tropicalisation is recommended for applications where both high relative humidity and high ambient temperatures exist
Weight: 3.2kg/7.1Ibs
Nominal
Voltage: Voltage
range: Nominal
current: In-rush:
24Vdc 20-28Vdc 853mA 753mA
48Vdc 42-54Vdc 330mA –
115Vac 110-120Vac 50/60Hz 310mA –
230Vac 220-240Vac 50/60Hz 170mA –
Part Code: Ident.: Description:
Product type: D1xB2
Type: X15 Xenon Strobe Beacon 15 Joule
Voltage: DC024
DC048
AC115
AC230 24V dc (20-28Vdc)
48Vdc (42-54Vdc)
115Vac (110-120Vac)
230Vac (220-240Vac)
Cable entries: [e] M Side: 2 × 3/4” NPT & 2 x M20x1.5
Pendant: 1 × 3/4” NPT
Stopping plug material: [m] B
N
S Brass
Nickel plated brass
Stainless steel
Lens guard & tag: [s] 1
2
3
4 A2 304 Stainless Steel
A4 316 Stainless Steel
A2 304 St/St with Equip. Tag
A4 316 St/St with Equip. Tag
Version: [v] A1
S1
T1 UL, cUL, ULC, IECEx, ATEX
IECEx, ATEX – SIL2 (24Vdc only)
UL, cUL, ULC, IECEx, ATEX – Tropicalised
Enclosure: [x] R
G
S Red RAL3000
Grey RAL7038
Special colour – contact E2S
Lens colour: [y] A, B, C
G, M, R
Y Amber, Blue, Clear
Green, Magenta, Red
Yellow
SP77-0001-A2-R or G
SP77-0001-A4-R or G
SP65-0001-A2 or A4
SP65-0003-A2 or A4
Multi angle wall bracket St/St A2 (304) Red or Grey
Multi angle wall bracket St/St A4 (316) Red or Grey
Pole Mount Bracket Kit 2″ St/St A2 (304) or A4 (316)
Sunshade – St/St A2 (304) or A4 (316)
SP77-0002
SP77-0015-R or G
SP77-0016-R or G Spare Xenon flash tube assembly
Spare Pack of 2 x Surface Mount Lugs Red or Grey
Spare Pack of 2 x Bracket mount hole plugs Red or Grey
ATEX / IECEx
II 2G Ex db IIC T3 Gb Ta -55°C to +80°C (AC: +65°C)
II 2G Ex db IIC T4 Gb Ta -55°C to +45°C
II 2D Ex tb IIIC T146°C Db Ta -55°C to +80°C (AC: T139°C +70°C)
NEC Class / Zone
Class I Zone 1 AEx db IIC T3 Ta -55°C to +80°C (AC: +65°C)
Class I Zone 1 AEx db IIC T4 Ta -55°C to +65°C
Zone 21 AEx tb IIIC T132°C Ta -55°C to +80°C (AC: T153°C +70°C)
CEC Class / Zone
Ex db IIC T3 Ta -55°C to +80°C (AC: +70°C)
Ex db IIC T4 Ta -55°C to +65°C
Ex tb IIIC T132°C Ta -55°C to +80°C (AC: T153°C +70°C)
NEC / CEC Class / Div
Class I Div 1 Group ABCD T3C Ta -55°C to +80°C (DC only)
Class I Div 1 Group ABCD T4 Ta -55°C to +55°C (AC: T4A +55°C)
Class II Div 1 Group EFG T4 Ta -55°C to +80°C (AC: +40°C)
Class III Div 1 Ta -55°C to +80°C (AC: +40°C)
CONTACT US