Four flash rates: 1Hz, 1.3Hz, 1.5Hz & double flash
Automatic synchronisation on multi-beacon system
User replaceable Xenon tube secured against shock & vibration
Stainless Steel guard included as standard
Field replaceable UV stable lens colour filter
Stopping plugs included
4 x side cable entries, 1 x pendant conduit entry
Duplicate cable terminations (in & out for daisy-chain installations)
UL 1638 Visible signaling devices for Fire Alarm
CAN/ULC S526 Visible signaling device for Fire Alarm
Source: Xenon Strobe
Energy: 15 Joules
Modes: 1Hz flash (60 fpm)
1.3Hz flash (80 fpm)
1.5Hz flash (90 fpm)
Double flash (120 fpm)
Eff. Intensity cd: 98.61cd UL1638 Private mode fire
Eff. Intensity cd: 731.71cd measured ref to I.E.S
Peak Intensity cd: 1,500,000 cd
Lens colours: Amber, Blue, Clear, Green, Magenta, Red & Yellow
Voltage DC: 24V dc (20-28Vdc), 48Vdc (42-54Vdc)
Voltage AC: 115Vac (110-120Vac), 230Vac (220-240Vac)
In-rush: 753mA within 6ms @ 24Vdc
Ingress protection: IP rating per EN60529:IP66
Type rating per UL50E/NEMA250:4/4X/3R/13
Enclosure matl: Marine grade LM6 aluminum alloy
Enclosure finish: Chromate & powder coated finish – anti-corrosion
Enclosure color: Red (RAL3000) or Grey (RAL7038)
Lens material: High impact Borosilicate glass
Cable entries: Side: 2 × 3/4″NPT & 2 x M20x1.5
Pendant: 1 × 3/4″NPT
Stopping plugs: Brass, Nickel Plated or Stainless Steel
Terminals: 0.5 – 2.5mm² (20-14 AWG)
Line monitoring: Blocking diode included
EOL can be factory or user installed
Installation temp: -55 to +80°C [-67° to +176°F]
Storage temp: -55 to +80°C [-67° to +176°F]
Relative humidity: 95% – Additional tropicalisation is recommended for applications where both high relative humidity and high ambient temperatures exist
Weight: 3.2kg/7.1Ibs
Nominal
Voltage: Voltage
range: Nominal
current: In-rush:
24Vdc 20-28Vdc 853mA 753mA
48Vdc 42-54Vdc 330mA –
115Vac 110-120Vac 50/60Hz 310mA –
230Vac 220-240Vac 50/60Hz 170mA –
Part Code: Ident.: Description:
Product type: D1xB2
Type: X15 Xenon Strobe Beacon 15 Joule
Voltage: DC024
DC048
AC115
AC230 24V dc (20-28Vdc)
48Vdc (42-54Vdc)
115Vac (110-120Vac)
230Vac (220-240Vac)
Cable entries: [e] M Side: 2 × 3/4” NPT & 2 x M20x1.5
Pendant: 1 × 3/4” NPT
Stopping plug material: [m] B
N
S Brass
Nickel plated brass
Stainless steel
Lens guard & tag: [s] 1
2
3
4 A2 304 Stainless Steel
A4 316 Stainless Steel
A2 304 St/St with Equip. Tag
A4 316 St/St with Equip. Tag
Version: [v] A1
S1
T1 UL, cUL, ULC, IECEx, ATEX
IECEx, ATEX – SIL2 (24Vdc only)
UL, cUL, ULC, IECEx, ATEX – Tropicalised
Enclosure: [x] R
G
S Red RAL3000
Grey RAL7038
Special colour – contact E2S
Lens colour: [y] A, B, C
G, M, R
Y Amber, Blue, Clear
Green, Magenta, Red
Yellow
SP77-0001-A2-R or G
SP77-0001-A4-R or G
SP65-0001-A2 or A4
SP65-0003-A2 or A4
Multi angle wall bracket St/St A2 (304) Red or Grey
Multi angle wall bracket St/St A4 (316) Red or Grey
Pole Mount Bracket Kit 2″ St/St A2 (304) or A4 (316)
Sunshade – St/St A2 (304) or A4 (316)
SP77-0002
SP77-0015-R or G
SP77-0016-R or G Spare Xenon flash tube assembly
Spare Pack of 2 x Surface Mount Lugs Red or Grey
Spare Pack of 2 x Bracket mount hole plugs Red or Grey
ATEX / IECEx
II 2G Ex db IIC T3 Gb Ta -55°C to +80°C (AC: +65°C)
II 2G Ex db IIC T4 Gb Ta -55°C to +45°C
II 2D Ex tb IIIC T146°C Db Ta -55°C to +80°C (AC: T139°C +70°C)
NEC Class / Zone
Class I Zone 1 AEx db IIC T3 Ta -55°C to +80°C (AC: +65°C)
Class I Zone 1 AEx db IIC T4 Ta -55°C to +65°C
Zone 21 AEx tb IIIC T132°C Ta -55°C to +80°C (AC: T153°C +70°C)
CEC Class / Zone
Ex db IIC T3 Ta -55°C to +80°C (AC: +70°C)
Ex db IIC T4 Ta -55°C to +65°C
Ex tb IIIC T132°C Ta -55°C to +80°C (AC: T153°C +70°C)
NEC / CEC Class / Div
Class I Div 1 Group ABCD T3C Ta -55°C to +80°C (DC only)
Class I Div 1 Group ABCD T4 Ta -55°C to +55°C (AC: T4A +55°C)
Class II Div 1 Group EFG T4 Ta -55°C to +80°C (AC: +40°C)
Class III Div 1 Ta -55°C to +80°C (AC: +40°C)
CONTACT US
To provide the best experiences, we and our partners use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us and our partners to process personal data such as browsing behavior or unique IDs on this site and show (non-) personalized ads. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Click below to consent to the above or make granular choices. Your choices will be applied to this site only. You can change your settings at any time, including withdrawing your consent, by using the toggles on the Cookie Policy, or by clicking on the manage consent button at the bottom of the screen.