The D371 is a stand-alone fire & flame detector in a watertight NEMA 4X (IP66/67) and explosion-proof Stainless Steel enclosure designed for indoor/outdoor Class I, Div. 1 (Zone 1) installations. The detector features an automatic self-test for continuously checking the detector’s optical path integrity while monitoring the electronics to ensure utmost reliable operation and fault reporting.Â
The D371 3IR +UV Multi-Spectrum Fire & Flame Detector (Patent pending) represents a new generation of optical fire & flame detector designed and optimized to respond to both the Hydrocarbon and Non-Hydrocarbon based fires while rejecting False Alarm Sources. The Protector D371 senses UV radiation in the Ultraviolet spectrum and Infrared radiation in 3 discrete bands of IR Spectrum for detecting fires.Â
Flame response and false source rejection for the detector is accomplished by utilizing the Convolution Method and Advanced DSP (Digital Signal Processing).
| Response Time | Detects fires in 3–5 seconds for rapid alerts and minimized risk. |
| Multi-Spectrum Detection | 3 IR + UV design detects hydrocarbon, non-hydrocarbon, and hydrogen fires with high false alarm immunity. |
| Outputs | Alarm, fault, and auxiliary relays; 4–20 mA analog output; RS485 Modbus®. |
| Event Logging | Stores 200 events and 6 FireGraphs® for tracking and analysis. |
| Adjustable Sensitivity | Multiple selectable sensitivity levels for varied operating environments. |
| Solar Blind & Heater | Solar blind technology with optional heater minimizes false alarms and prevents condensation or icing. |
| Automatic Self-Test | OptiRadar® technology continuously monitors circuitry and optical path integrity. |
| Enclosure | Copper-free aluminum or stainless steel housing with NEMA 4/4X (IP66/IP67) and explosion-proof options. |
| Installation | Pluggable connector and modular electronics simplify installation and maintenance. |
| Warranty | Made in the USA with a 3-Year Warranty. |
| General | |
|---|---|
| Field of View | 90° Horizontal and Vertical |
| Spectral Sensitivity | UV: 180–260 nm; IR: 2–5 µm (3 discrete bands) |
| Detection Range | 12 × 12 in n-Heptane fire: 200 ft (61 m); 36 in Hydrogen Plume: 100 ft (30.5 m) |
| Response Time | Typically 3–5 seconds |
| Electrical | |
|---|---|
| Operating Voltage | 24 VDC nominal (18–31 VDC), regulated |
| Standby Power | 60 mA @ 24 VDC |
| Alarm Power | 90 mA @ 24 VDC |
| Heater Option | 120 mA additional |
| Mechanical | |
|---|---|
| Enclosure | 316 Stainless Steel |
| Dimensions | 5.91 × 4.78 × 4.40 in (150 × 122 × 112 mm) |
| Weight | 10 lb (4.5 kg) |
| Mounting | Stainless steel swivel arm (order separately #DA-001), 6.6 lb (3 kg) |
| Conduit Entries | Standard: (2) M25; 1 × M25 × ¾ in NPT adapter included |
| Wiring | 12–22 AWG (3.3–0.33 mm²) |
| Environmental | |
|---|---|
| Operating Temperature | -40°F to +185°F (-40°C to +85°C); -55°F to +185°F (-48.3°C to +85°C) with heater option |
| Operating Humidity | 5–95% RH, non-condensing |
| Vibration | In compliance with FM 3260-2003; meets or exceeds MIL-STD 810C |
| Enclosure Type | NEMA 4 & 4X, IP66/IP67 |
| Relay Operations | |
|---|---|
| Output Relays | Alarm / Auxiliary / Fault; SPDT contacts rated 2 A @ 24 VDC. Alarm & Auxiliary programmable; Fault energized. |
| Adjustable Time / Verification Delay | Auxiliary Relay: 0.3, 3, 10, 20 seconds |
| Analog Output | 0–20 mA stepped source |
| Communication | RS-485 Modbus |
| Visual Indications | Green LED (Normal); Red LED (Alarm) |
| Airports & Aircraft Hangars |
| Warehouse & Storage Facilities |
| Manufacturing & Food Processing |
| Diesel Generators & Fuel Storage |
| Battery Rooms & Charging Facilities |
| Oil & Gas Facilities |
| Refineries & Cogeneration Plants |
| Chemical & Hydrogen Plants |
| Tank Farms |
| Compressor Stations |
| Paint Booths |
| Paint & Solvent Storage Facilities |
| Recycling Centers |
| LPG / LNG Facilities |
| Power Plants |
| Marine Fuel Loading & Unloading |
| FM Approval | FM Approved (USA & Canada) |
| EMC / RFI Compliance | RFI & EMC compliant |
| SIL Rating | Designed to SIL 3 requirements |
| ATEX Certification | ATEX Certified |
| IEC / IECEx Certification | IEC / IECEx Certified |
| CE Marking | CE Marked |
| CSFM Listing | California State Fire Marshal (CSFM) Listing |
| Environmental Testing | Meets or exceeds MIL-STD 810C |
| Flame Detector Standard | In compliance with FM3260-2003 |
| DA-001 | 316 Stainless Steel Mounting Arm |
| DA-003 | Air Purge Kit |
| DA-005 | Weather Shield |
| DA-006 | Field of View Restrictor |
| DA-008 | Detector Key Test Station |
| HW-AM25-0001 | M25 Male to ¾ in Female Adapter, Stainless Steel |
Looking for dependable gas detection and control solutions at the right price, without the long wait? Conspec offers industry-leading turnaround times and competitive pricing on all of our safety solutions. Please share some information about your project and a member of our team will respond at their earliest convenience.
"*" indicates required fields
To provide the best experiences, we and our partners use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us and our partners to process personal data such as browsing behavior or unique IDs on this site and show (non-) personalized ads. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Click below to consent to the above or make granular choices. Your choices will be applied to this site only. You can change your settings at any time, including withdrawing your consent, by using the toggles on the Cookie Policy, or by clicking on the manage consent button at the bottom of the screen.